1 00:00:00,000 --> 00:00:02,583 (upbeat music) 2 00:00:09,116 --> 00:00:11,480 - [Instructor] Thanks to some of the latest research 3 00:00:11,480 --> 00:00:15,060 from engineers with the Center for Transportation Research, 4 00:00:15,060 --> 00:00:19,150 bridge designers can now build more economical structures. 5 00:00:19,150 --> 00:00:20,700 As part of this project 6 00:00:20,700 --> 00:00:22,920 a new analytical method was developed 7 00:00:22,920 --> 00:00:25,230 that proves TxDOT bridge beams 8 00:00:25,230 --> 00:00:27,430 have a higher load carrying capacity 9 00:00:27,430 --> 00:00:29,030 than previously thought. 10 00:00:29,030 --> 00:00:31,440 - So in our current analysis method 11 00:00:31,440 --> 00:00:33,080 there's a provision in the spec 12 00:00:33,080 --> 00:00:36,680 that limits the shear stress at our beam ends 13 00:00:36,680 --> 00:00:38,810 and when we exceed this, the spec tells us 14 00:00:38,810 --> 00:00:41,600 that we have to do a strut-and-tie analysis. 15 00:00:41,600 --> 00:00:44,960 The strut-and-tie analysis is very calculation intensive. 16 00:00:44,960 --> 00:00:46,810 So most designers opt to not do it 17 00:00:46,810 --> 00:00:50,440 and just add in a beam line to reduce the shear stress. 18 00:00:50,440 --> 00:00:54,200 So adding in this beam line adds cost to the project. 19 00:00:54,200 --> 00:00:57,620 - If you can permit a higher level of shear stress 20 00:00:57,620 --> 00:01:00,860 in a typical bridge design where the span lengths 21 00:01:00,860 --> 00:01:04,320 are being pushed to their extremes, 22 00:01:04,320 --> 00:01:07,030 you can actually eliminate a beam line. 23 00:01:07,030 --> 00:01:09,780 And if you're eliminating a beam line in this bridge, 24 00:01:09,780 --> 00:01:12,840 a beam line in the next bridge, and some other bridges 25 00:01:12,840 --> 00:01:15,210 before you know it with those settings, 26 00:01:15,210 --> 00:01:19,100 you can construct another bridge to serve communities 27 00:01:19,100 --> 00:01:21,510 faster, better in the state of Texas. 28 00:01:21,510 --> 00:01:23,900 - So what we did here is we had the researchers 29 00:01:23,900 --> 00:01:27,320 look at the strut-and-tie models of all the beam ends 30 00:01:27,320 --> 00:01:29,260 of all of our standard beams 31 00:01:29,260 --> 00:01:31,670 and let us know when the strut-and-tie model 32 00:01:31,670 --> 00:01:34,740 tells us that you can't go above a certain shear stress. 33 00:01:34,740 --> 00:01:36,600 - We constructed a variety 34 00:01:36,600 --> 00:01:38,430 of different strut-and-tie models 35 00:01:38,430 --> 00:01:43,430 for different types of standard precast concrete builders 36 00:01:43,700 --> 00:01:48,700 and we were able to change that limiting shear stress 37 00:01:49,120 --> 00:01:51,420 from 18% to some cases 38 00:01:51,420 --> 00:01:54,800 where we can go all way up to 25%, 39 00:01:54,800 --> 00:01:58,490 in other cases greater than 18 but less than 25. 40 00:01:58,490 --> 00:02:01,220 - This will help us reduce the number of beam lines 41 00:02:01,220 --> 00:02:03,380 which will reduce the cost of projects 42 00:02:03,380 --> 00:02:04,850 specifically on projects 43 00:02:04,850 --> 00:02:06,660 where we're stretching the span limits. 44 00:02:06,660 --> 00:02:09,960 - The result of this work can really be summarized 45 00:02:09,960 --> 00:02:12,370 and has been summarized in a simple table 46 00:02:12,370 --> 00:02:15,950 where a TxDOT will be able to better use 47 00:02:15,950 --> 00:02:20,950 its precast concrete sections to their actual capacities 48 00:02:21,120 --> 00:02:24,870 as opposed to the more conservative 49 00:02:24,870 --> 00:02:26,560 way of handling this problem. 50 00:02:26,560 --> 00:02:28,220 - This is a really early stage. 51 00:02:28,220 --> 00:02:30,240 The research has just completed. 52 00:02:30,240 --> 00:02:32,170 So we need to review it in house 53 00:02:32,170 --> 00:02:34,700 and determine how we're going to implement it. 54 00:02:34,700 --> 00:02:36,450 Right now the researchers have suggested 55 00:02:36,450 --> 00:02:39,210 different stress limits for each individual beam. 56 00:02:39,210 --> 00:02:41,360 So it's likely that we would combine them together 57 00:02:41,360 --> 00:02:42,887 and make it a bit more simple. 58 00:02:42,887 --> 00:02:44,340 - [Instructor] For more information 59 00:02:44,340 --> 00:02:46,870 and to find the publications for this project 60 00:02:46,870 --> 00:02:49,760 please visit the TxDOT Research Library 61 00:02:49,760 --> 00:02:51,303 at the link shown below.